Typical Maximum Read Range*
ProxCard® II Card - up to 8" (20
cm)
ISOProx® II Card - up to 7" (17.5 cm)
DuoProx® II Card - up to 7"
(17.5 cm)
Smart ISOProx® II Card - up to 7" (17.5 cm)
Smart DuoProx® II
Card – up to 7" (17.5 cm)
HID Proximity & MIFARE® card – up to 7" (17.5
cm)
ProxCard® Plus Card - up to 3" (7.5 cm)
ProxKey® II Keyfob - up to 3"
(7.5 cm)
MicroProx® Tag – up to 4" (10.2 cm)
ProxPass® Active Vehicle Tag
– N/A
*Depending on local installation
conditions.
Dimensions
5.0" x 5.0" x 1.0" (12.7 x 12.7 x 2.54
cm)
Power Supply
10-28.5 VDC; Linear power supplies
recommended. Reverse voltage protection included.
Current
Requirements
Average: 100 mA (12 VDC)
Peak: 120 mA (24
VDC)
Operating Temperature
-22° to 150° F (-30° to 65°
C)
Operating Humidity
0-95% relative humidity
non-condensing
Weight
12 oz. (336 gm)
Cable
Distance
Wiegand or Clock and Data interface: 500 feet (152 m)
RS-232
interface: 50 feet (15 m)
RS-422 interface: 4000 feet (1219 m)
Recommended
cable is ALPHA 1295 (22 AWG) 5 conductor stranded with overall shield or
equivalent.
Additional conductors may be required for LED or beeper control.
RS-422 requires ALPHA 6212C 2-Twisted Pair, shielded cable with drain wire, or
equivalent for data, plus ALPHA 1292C two-conductor shielded or equivalent for
DC power.
Certifications
Canada/UL 294 Listed: Access Control System
Units
FCC Certification, United States
Canada Certification
CE Mark,
Fifteen EU Countries under the R&TTE
Directive (EN60950 - ITE Electrical
Safety, EN 300 330 - SRD, and ETS 300 683 - EMC)
IEC60950, ITE CB Scheme
Electrical Safety
Australia C-Tick Mark, New Zealand EMC, China
Taiwan
(5355 only)